Updating Your RB-x30 Response
Pad Software for Use With E-Prime
Last
Revision: May 4, 2004
The information in this article applies to:
Owners
of an RB-530,
RB-730, RB-830, or
RB-834 response pad who need to update
the response pad's software in order to use it with E-Prime
Summary
Unfortunately, version 1.2
of the XID software that controls the RB-x30 response pads contains a bug
that prevents the response pad from working properly with E-Prime. This page
provides the necessary instructions to update the XID software to version
1.4. Updating the software
essentially consists of the downloading a program called Xidon (pronounced
Zydon) and running it.
We want to help. If you
are uncomfortable in any way performing this update, please send us back the
response pad and we will gladly update it for you.
The Details
Before proceeding, the USB
driver must be already installed. If it is not, please
install it now.
1. Take a look at
the back of your response pad, illustrated below. You will find a set of four switches
near the middle. Make sure that all four switches are down.

2. Unplug the USB cable
from the response pad (if it's already plugged in), wait two or three
seconds, then plug it back in. The small green
light to the right of the switches should turn on. If it does
not, this indicates that the USB driver is not installed: please
install it now before proceeding.
3. You will need the
Xidon program. Click here
to install it on your computer. You don't have to save the install program
on your computer unless you want to; we recommend that you simply run it
from our server.
4. Once Xidon is
installed, click on the Start button, click on All Programs,
click the Xidon folder, then click on the Xidon icon to
run the program. When Xidon runs, a small dialog (screen) opens.
5. The startup dialog has
a button labeled Auto Detect. Click on it. Xidon will start scanning
all the serial ports and USB ports until it finds the response pad.
6. Once found, the OK
button will no longer be gray. Click on it. The dialog will go away.
7. In Xidon, click on the
Device menu and select the last item on that menu, Update Firmware.
8. Xidon will display an
"open file" dialog asking you to "Please Locate the HEX File:". Select the
file RBX30_c14c.hex and then click on the
Open button.
9. At this point,
updating the response pad's software begins and a "downloader" window
similar to the one below appears:

10. Once the updating is
complete, the downloader window will close automatically. At this point,
exit the Xidon program (do not try to use it after a download, it will
not work; you will need to re-run it if you want to use some of its
features).
11. Unplug the USB cable
from the response pad.
12. In the set of four
switches near the middle, turn switch 1 UP. This will make your response pad
E-Prime compatible.
13. Plug the USB cable
into the response pad. The small green
light to the right of the switches should turn on.
You response pad is now ready to use with E-Prime.
|