Technical Details

The 4 MHz microcontroller inside the response pads keeps an eye on the the status of the keys and sends one byte to the host every time a key is pressed or released. In other words, when a key is pressed, a byte is sent. When the key is released, another byte is sent. Each bit within the byte corresponds to a key.

The built-in microcontroller takes care of debouncing the keys if necessary. This guarantees that, when a key is pressed, one and only one byte is sent to the host instead of a stream.

The byte sent from the RB-400, RB-410, and RB-420 models has the following format:

Bit

RB-4x0 Function

0

Always set

1

Always set

2

Cleared when leftmost button is pressed (normally set)

3

Cleared when second button from the left is pressed

4

Cleared when third button from the left is pressed

5

Cleared when rightmost button is pressed

6

Always cleared

7

Always cleared

The byte sent from the RB-600, RB-610, and RB-620 models has the following format:

Bit

RB-6x0 Function

0

Cleared when leftmost button is pressed (normally set)

1

Cleared when rightmost button is pressed

2

Cleared when second button from the left is pressed

3

Cleared when third button from the left is pressed

4

Cleared when fourth button from the left is pressed

5

Cleared when fifth button from the left is pressed

6

Always cleared

7

Always cleared

The byte sent from the RB-520 model has the following format:

Bit

RB-520 Function

0

Always set

1

Cleared when the top button is pressed

2

Cleared when the left button is pressed

3

Cleared when the center button is pressed

4

Cleared when the right button is pressed

5

Cleared when fifth button from the left is pressed

6

Cleared when the bottom button is pressed

7

Always set

The byte sent from the RB-820 model has the following format:

Bit

RB-820 Function

0

Cleared when rightmost button is pressed

1

Cleared when third button from the left is pressed

2

Cleared when second button from the left is pressed

3

 

4

Cleared when fourth button from the left is pressed

5

Cleared when fifth button from the left is pressed

6

 

7

Cleared when leftmost button is pressed